MAN Diesel Engines for Power Generation

Customer Benefits on MAN Diesel-Powered Generators
  • ABET Co. is a strong and independent partner for packagers and offers high quality MAN engines made in Germany
  • Global after sales network guarentees short-term spare parts supply
  • Eco-friendly operation as a result of lower consumption of fuel and lubricating oil
  • MAN engines with high efficiency, reliability and low maintenance costs result in profitable prime power operation especially in emerging markets
  • MAN engines for standby operation to provide maximum power output with quick load acceptance in case of power shortage
  • Ideal balance between compact design and robust construction allows smaller size of container gensets with high durability


Emergency Standby Power (ESP)
  • Power output available with varying load for the duration of an emergency outage.
  • Average power output is 70 % of the emergency standby power rating.
  • Typical operation is 50 hours per year with maximum expected usage of 200 hours per year.
  • Standby power in accordance with ISO 8528.
  • Fuel stop power in accordance with ISO 3046.

Limited Time Power (LTP)
  • Power output available with varying load for the duration of the interruption of the normal source power.
  • Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year, within the following limits of maximum operating time: 100 % load 50 hours per year and 90 % load 200 hours per year.
  • No overload available.
  • Fuel stop power in accordance with ISO 3046.

Prime Power (PRP)
  • Power output available with varying load for unlimited time. Average power output is 80 % of the prime power rating.
  • With 10 % overload capability for technical purposes for a maximum of one hour in twelve.
  • Overload operation cannot exceed 50  hours per year.
  • Prime power in accordance with ISO 8528.
  • Fuel stop power in accordance with ISO 3046.

Continuous Power (COP)
  • Power output available without varying load for unlimited time. Average power output is 100 % of the continuous power rating.
  • With 10 % overload capability for technical purposes for a maximum of one hour in twelve.
  • Continuous power is in accordance with ISO 8528.
  • Fuel stop power in accordance with ISO 3046



Diesel engines for ESP, LTP, PRP and COP

Engine          Cylinder(s)   Arrangement      Capacity (l)       ESP            LTP              PRP             COP
D2866                      6              in-line              11.9             360–400     308–354     280–322     180–220
D2876                      6              in-line              12.8             451–507     391–446     355–405     220–265
D2676                      6              in-line              12.4             415–440     396–415     360–377     270–283
D2848                      8              V 90°               14.6             495–539     446–506     405–460     270–350
D2840                      10            V 90°               18.3             545–660     496–622     451–565     310–435
D2842                      12            V 90°               21.9             633–800     597–765     543–695     390–530
D2862                      12            V 90°               24.2           880–1 117     770–920     700–836     560–640